Maintenance
174
XS728T ProSAFE 28-Port 10-Gigabit L2+ Smart Switch
• MaxFail. Specify the maximum number of failures allowed in the session. The default
value is 5. The range is 0 to 255. The MaxFail you enter is not retained across a power
cycle.
• Interval (secs). Specify the time between probes in seconds. The default value is 3.
The range is 1 to 60. The Interval you enter is not retained across a power cycle.
• Port. Specify the UDP destination port in probe packets. The default value is 33434.
The range is 1- 65535. The port you enter is not retained across a power cycle.
• Size. Specify the size of probe packets. The default value is 0. The range is 64 to 1472.
The Size you enter is not retained across a power cycle.
4. Click Apply to initiate the traceroute. The results display in the Results field.
Traceroute IPv6
Use this screen to tell the switch to send a TraceRoute request to a specified IPv6 address or
Hostname. You can use this to discover the paths packets take to a remote destination. Once
you click the Apply button, the switch will send a traceroute and the results will be displayed
below the configurable data.
If a reply to the traceroute is received, the following is a sample of what may be displayed.
1 10.5.225.33 20 ms 10 ms 30 ms
2 10.5.225.225 10 ms 10 ms 10 ms
3 192.254.254.3 10 ms 30 ms 20 ms
Hop Count = 3 Test attempt = 9 Test Success = 3
To display the Traceroute IPv6 page.
1. Click Maintenance > Troubleshooting > Traceroute IPv6.
2. Use IPv6 Address/Hostname to enter the IPv6 address or hostname of the station you
want the switch to discover path. The initial value is blank. The IPv6 address must be a
Global one. The IPv6 Address or Hostname you enter is not retained across a power cycle.
3. Configure the following settings:
• Probes Per Hop. Specify the number of times each hop must be probed. The valid
range is 1–10. The default value is 3.
• MaxTTL. Specify the maximum time-to-live for a packet in number of hops. The valid
range is 1–255. The default value is 30.
• InitTTL. Specify the initial time-to-live for a packet in number of hops. The valid range
is 1–255.The default value is 1. The InitTTL you enter is not retained across a power
cycle.
• MaxFail. Specify the maximum number of failures allowed in the session. The default
value is 5. The range is 0 to 255. The MaxFail you enter is not retained across a power
cycle.
• Interval (secs). Specify the time between probes in seconds. The default value is 3.
The range is 1 to 60. The Interval you enter is not retained across a power cycle.
• Port. Specify the UDP destination port in probe packets. The default value is 33434.
The range is 1- 65535. The port you enter is not retained across a power cycle.