5-4 BA 6001/9001/10001 En – Edition 2.0 * * 6001b510.fm
Maintenance
Stationary fuel pumps
General
Only refuel from stationary fuel pumps. Fuel from barrels or cans is usually contaminated.
Even the smallest particles of dirt can cause
• Increased engine wear
• Malfunctions in the fuel system and
• Reduced effectiveness of the fuel filters
Refuelling from barrels
If refuelling from barrels cannot be avoided, note the following points (see fig. 15):
• Barrels must neither be rolled nor tilted before refuelling
• Protect the suction pipe opening of the barrel pump with a fine-mesh strainer
• Immerse it down to a max. 15 cm above the floor of the barrel
• Only fill the tank using refuelling aids (funnels or filler pipes) with integral microfilter
• Keep all refuelling containers clean at all times
Diesel fuel specification
Use only high-grade fuels
wrong
right
Fig. 15: Refuelling from a barrel
Grade
Cetane
number
Use
• No. 2-D according to DIN
51601
Min. 45
For normal outside temperatures
• No. 1-D according to DIN
51601
For outside temperatures below 4 °C
(39.2°F) or for operation above 1500 m
(0.93 mialtitude