EasyManua.ls Logo

Neuson 6001 - Maintenance Plan (Overview)

Neuson 6001
134 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BA 6001/9001/10001 En – Edition 2.0 * * 6001b540.fm 5-35
Maintenance
5.15 Maintenance plan (overview)
Work description
For service and maintenance work on the attachment, please refer to the operation and maintenance manual of the attachment
manufacturer as well.
Maintenance plan/service hours (s/h)
Maintenance work
(once a day)
Every 50 s/h
Every 500 s/h
Once a year or after 1000 s/h
After 1500 s/h
Customer
Fluid and filter changes ( ):
Carry out the following oil and filter changes (check oil levels after test run):
Engine oil
1
Engine oil filter
2
Fuel filter
3
Air filter element
•Coolant
Hydraulic oil filter insert
4
Hydraulic oil
Hydraulic oil tank breather
Inspection work ( ):
Check the following material. Refill if necessary:
Engine oil
Engine coolant
Hydraulic oil
Clean the water ducts
5
Check cooler for engine and hydraulic oil for contamination. Clean if necessary
Check cooling systems, heating and hoses for leaks and pressure (visual check)
Air filter (damage)
Check the air filter, clean if necessary
Prefilter with water separator: drain water
•Clean
Check V-belt condition and tension
Check V-belt condition and tension
Maintenance