41
Table 8. Interrupt Request Settings for GPIB-PCII/IIA in PCIIA Mode
Interrupt
Line
Switch Jumper
Interrupt
Line
Switch Jumper
2 3
4 5
I2
I1
I0
U210
1 26897345
OFF
I2
I1
I0
U210
1 26897345
OFF
IRQ2
IRQ3
IRQ4
IRQ5
IRQ6
IRQ7
I2
I1
I0
U210
1 26897345
OFF
IRQ2
IRQ3
IRQ4
IRQ5
IRQ6
IRQ7
I2
I1
I0
U210
1 26897345
OFF
IRQ2
IRQ3
IRQ4
IRQ5
IRQ6
IRQ7
I2
I1
I0
U210
1 26897345
OFF
IRQ2
IRQ3
IRQ4
IRQ5
IRQ6
IRQ7
The remaining steps in the installation and configuration process are the same for GPIB-PCII mode
and GPIB-PCIIA mode. Click here to go to the section Configure the GPIB-PCII/IIA DMA Channel,
and continue configuring and installing your GPIB-PCII/IIA.
View Parts
Locator
Diagram

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NI GPIB Series and is the answer not in the manual?

NI GPIB Series Specifications

General IconGeneral
Operating Systems SupportedWindows, Linux, macOS
Driver SoftwareNI-488.2
Bus InterfaceIEEE 488
Data Transfer RateUp to 8 MB/s
CompatibilityIEEE 488.1, IEEE 488.2
Connector Type24-pin IEEE 488 connector
Maximum Cable Length20 m total system length
Number of Devices SupportedUp to 14 devices per bus