Page #40 background imageLoading...
Page #40 background image
HOME
TitleShort-Hidden -40
©
National Instruments Corporation
Configure and Install Your GPIB-PCII/IIA
Next
Step
Previous
Step
40
Configure the GPIB-PCII/IIA Interrupt Line (IRQ) (GPIB-PCIIA Mode)
Click on the interrupt line (IRQ) setting assigned to your GPIB-PCII/IIA from the list below, and
change the jumper and switch settings to match the interrupt line (IRQ) assigned to your board.
By default, the GPIB-PCII/IIA is configured to use interrupt request line IRQ 7.
If you do not know what resources were assigned to your GPIB-PCII/IIA, click here to Determine
Assigned Resources.
234
567
Interrupt Disabled

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the NI GPIB Series and is the answer not in the manual?

NI GPIB Series Specifications

General IconGeneral
Operating Systems SupportedWindows, Linux, macOS
Driver SoftwareNI-488.2
Bus InterfaceIEEE 488
Data Transfer RateUp to 8 MB/s
CompatibilityIEEE 488.1, IEEE 488.2
Connector Type24-pin IEEE 488 connector
Maximum Cable Length20 m total system length
Number of Devices SupportedUp to 14 devices per bus