Electrical System 45Service Manual – SC2000
Maintenance and Adjustments
Setting the Installed Battery Type
Setthemachineandtheon-boardbatterycharger(wheretted)onthebasisofthetypeofbatterytobein-
stalled by modifying the BAT parameter as shown.
1. Insert the super user key (yellow) in place of the operator key (grey) to access the main screen (Figure 4)
of the multifunction display.
2. Press the One-Touch button to continue to the machine settings screen (Figure 5).
Figure 4
Figure 5
3. Press the One-Touch button until you reach the BAT parameter.
MODIFIABLE PARAMETERS
Code Description Min. Value Factory Setting Max. Value
BAT Installed battery type 0 1 5
4. Press the vacuum system button or brush engagement/disengagement button to modify the
value of the BAT parameter as per the following table:
Code BAT
Value Installed battery type
0 WET Wet cell batteries
1 GEL / AGM Generic GEL or AGM batteries
2 GEL EXIDE EXIDE
®
/SONNENSHINE brand GEL batteries
3 GEL OPTIMA OPTIMA™ brand GEL batteries
4 GEL DISCOVER DISCOVER
®
brand GEL batteries
5 GEL FULLRIVER FULLRIVER
®
brand GEL batteries
5. Press the One-Touch button formorethan1secondtoconrmthechosenparameterandreturn
to the main screen (Figure 4).