Squeegee System 91Service Manual – SC2000
Troubleshooting
Trouble Possible Causes Remedy
Suction of dirty water is insufcient or
non-existent
Squeegee or vacuum hose clogged or damaged Clean or repair/replace
The squeegee leaves lining on the oor
or does not collect water
There is debris under the blade Remove
Squeegee blade lips damaged or worn Replace
Squeegee not balanced Adjust with the relevant handwheel
The squeegee cannot be lifted/lowered See the chapter Control System,
Function Electronic Board (EB1)
Error Codes
Squeegee lifting/lowering actuator (M6) broken Replace
Break in actuator wiring Check the connections according
to the instructions in the Electrical
System chapter, Troubleshooting
paragraph
Function electronic board (EB1) damaged Replace