EasyManua.ls Logo

Nilfisk-Advance SC2000 - EcoFlex System Draining; Fuse Check and Replacement

Nilfisk-Advance SC2000
107 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Solution System 83Service Manual – SC2000
Detergent Pump Disassembly/Assembly
Disassembly
1. Drive the machine on a level oor.
2. Switch off the machine and disconnect the battery connector.
3. Lift the recovery tank assembly and the driver’s seat, then disassemble the electronic component
compartment cover.
4. Disconnect the connectors (A), the tank hose (B) and brush hose (C).
5. Unscrew the two screws (D) and remove the detergent pump (E).
Assembly
6. Assemble the components in the reverse order of disassembly, ensuring the supply hoses (B) and (C) are
correctly tted on the detergent pump.
Figure 9
B
D
C
D
E
A