EasyManua.ls Logo

Nitty-Gritty Clinox PRO x2 - Installing Inserts and Brush Adapters

Default Icon
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22
NITTY GRITTY.IT
make it shine
A
B
C
CLINOX PRO • AIR • POWER • SURFACE
USER MANUAL
4.2. 
Take the desired insert or brush adapter.
In the back of the insert (or adapter) there are the two
countersinks (A) where the torch coupling grub screws will
be tightened.
Before positioning the insert (or adapter) on the torch
coupling, make sure that the O-ring seal is in place (B).
Place the insert (or adapter) on the torch coupling and
tighten the two grub screws with a 2.5 mm hex wrench (C);
make sure the grub screws are properly aligned with the
countersinks (A).
4.3. 
The electrodes reach very high
temperatures during the processing
operations.
If it is necessary to change the orientation of
the insert, take care to prevent burns to the
hands.
To facilitate processing when the surfaces to be treated have
particular shapes or are located in places that are di󰀩cult to
access, it is possible to adjust the torch coupling to arrange
the insert in a more comfortable position.
The insert can be rotated about ±90° with respect to the
horizontal position.