In the event of accidental exposure to electrolyte solutions or fumes produced during processing, please remain calm and
avoid any unintentional or harmful actions. It is recommended that you comply with the following guidelines:
In the case of inhalation of processing fumes, try to ensure an inow of fresh air into the respiratory tract and aerate the
surrounding environment when possible. If there are any subsequent respiratory tract complaints, seek medical advice.
If the skin comes into contact with acid solutions, wash it immediately with running water and soap; if after drying you
experience persistent skin irritation, consult a dermatologist or doctor.
If acid solutions are swallowed, it is better not to induce vomiting. Call an ambulance immediately and in the meantime
repeatedly rinse your mouth and then drink copious amounts of water.
If a certain amount of electrolyte comes into contact with your eyes, rinse your face thoroughly while trying to keep your
eyes open. Repeat the operation for several minutes. Use an emergency eyewash if available. If possible, remove any
contact lenses and continue rinsing. If irritation or subsequent visual complaints persist, consult an ophthalmologist or
doctor immediately.
1.2. 
1.3. 
The risks involved in the use of x2 line devices are signicantly reduced if both the safety rules indicated in chapter 1.1 and
the instructions for use shown in this manual are followed.
However, there are still risks arising from the high temperature reached by the electrode, possible contact with electrolyte
solutions and the operator's potential exposure to harmful fumes generated during processing; therefore, it is advisable to
always follow all the safety procedures described in this chapter.
THERMAL PROTECTION
All x2 line units are protected by a suitably positioned safety
device, which comes into action in the event of excessive
overheating of the inverter.
When this system intervenes, the appliance switches o󰀨
immediately and cannot be restarted until it has cooled
down; once the temperature has returned to normal levels,
the operation of the unit will be restored automatically.
PROTECTION AGAINST SHORT CIRCUITS
All x2 line units are equipped with a device protecting
against short circuits that can occur between the insert
installed on the torch and the workpiece, in particular when
the currents involved are high.
In the rare cases in which this happens, the system is
designed to automatically intervene and terminate the ow
of current to the torch; in this way the device electronic parts
are safeguarded.
The operation of the unit is restored immediately once the
electrode has been removed from the workpiece; to prevent
the appliance from locking again, it is advisable to check the
state of wear of the consumables (such as the felts) or to
use lower working voltages.
Do not disable and/or bypass the device's built-in protection systems.