Table 5-10 XS-2426X-A indoor ONT environmental specifications
Mounting method Temperature range and humidity Altitude
On desk or shelf Operating: 23°F to 113°F (-5°C to 45°C) ambient
temperature
90% humidity at 40°C
Contact your Nokia technical support representative for
more information
Storage: -4°F to 158°F (-20°C to 70°C)
5.8 XS-2426X-A GEM ports and T-CONTs
Table 5-11, “XS-2426X-A indoor ONT capacity for GEM ports and T-CONTs” (p. 56) lists the
maximum number of supported T-CONTs and GEM ports. See the appropriate release Customer
Release Notes for the most accurate list of supported devices.
Table 5-11 XS-2426X-A indoor ONT capacity for GEM ports and T-CONTs
ONT or MDU Maximum Notes
Package P ONTs
GEM ports per indoor or outdoor ONT 32 256 are present; 254 are available, and 2 are reserved for
multicast and debugging
T-CONTs per indoor or outdoor ONT 32 32 are present; 31 are available, and 1 is reserved for
OMCI
5.9 XS-2426X-A performance monitoring statistics
The following section identifies the supported performance monitoring statistics for the XS-
2426X-A. A check mark indicates the statistic is supported on that ONT. An empty cell indicates the
statistic is not supported. A cell without a check mark indicates the counter is not applicable to that
type of ONT. The following tables are categorized by supported counters types:
•
Table 5-12, “XS-2426X-A ONT generic performance monitoring statistics” (p. 56) provides
statistics for generic ONT type counters
• Table 5-13, “XS-2426X-A ONT ONTL2UNI performance monitoring statistics” (p. 57) provides
statistics for ONTL2UNI type counters
Table 5-12 XS-2426X-A ONT generic performance monitoring statistics
ONT Generic statistics
CPU
Memory utilization
XS-2426X-A ✓ ✓
XS-2426X-A unit data sheet
XS-2426X-A GEM ports and T-CONTs
Nokia ONT
Review Review
© 2021 Nokia. Nokia Confidential Information
Use subject to agreed restrictions on disclosure and use.
3FE-49546-AAAA-TCZZA
December 2021