104 BU 0800 en-4521
P543 Bus actual value S P
Setting range
0 … 57
Arrays
[-01] =
Actual bus value 1
[-02] =
Actual bus value 2
[-03] =
Actual bus value 3
[-04] =
Actual bus value 4
[-05] =
Actual bus value 5
Factory setting
[-01] = { 1 }
[-02] = { 4 }
[-03] = { 9 }
[-04] = { 0 }
[-05] = { 0 }
Description
Setting of the return values for bus control.
Setting values
Value / Meaning
0
Off
14
Setp. pos.HighWord
1)
1 Actual frequency 15 Cur.pos.Inc.HighWord
1)
2 Actual speed 16 Set.pos.Inc.HighWord
1)
3
Current
19
Freq. Master Value
4
Torque current
20
Set Freq. After Ramp
5
State digital-IO
21
Act. Freq. w/o Slip
6 Current pos.LowWord
1)
22 Speed encoder
1)
7
Setpoint pos.LowWord
1)
23
Act. freq. With slip
8
Set point frequency
24
Lead.act.freq.+slip
9
Error code
53
Actual value 1 PLC
10 Curr.pos.Inc.LowWord
1)
54 Actual value 2 PLC
11 Setp.pos.Inc.LowWord
1)
55 Actual value 3 PLC
12
BusIO Out Bits 0-7
56
Actual value 4 PLC
13
Current pos.HighWord
1)
57
Actual value 5 PLC
1)
Only for NORDAC ON+
P546 Funct. Bus set point S P
Setting range
0 … 57
Arrays
[-01] =
Bus set point 1
[-02] =
Bus set point 2
[-03] =
Bus set point 3
[-04] =
Bus set point 4
[-05] =
Bus set point 5
Factory setting
[-01] = { 1 }
All other { 0 }
Description
Assignment of a function to a bus set point value.
Setting values
Value
0 Off 14 Cur.val process ctrl
1 Setpoint frequency 15 Nom.val process ctrl
2
Torque current limit (P112)
16
Add. process control
3
PID current freq.
17
BusI/O In Bits 0…7
4 Frequency addition 19 Set relays (as P541)
5 Freq. subtraction 46 PI process controller, “Torque
6
Current limit (P536)
48
Motor temperature
7
Maximum frequency (P105)
49
Ramp time (acceleration and deceleration)
8 PID current freq. limited 53 d-correction, F process
9 PID current freq. monitored 54 d-correction Torque
10
Servo mode Torque
55
d-correction, F+ Torque
11
Torque precontrol (P214)
56
Acceleration time
13 Multiplication 57 Deceleration time

Table of Contents