Troubleshooting
6-9
Part 1107600_03
2014 Nordson Corporation
To change a motor drive parameter
See Figure 6‐2.
1. Press the jog dial button.
The display shows rEF.
2. Rotate the jog dial clockwise until the display shows the menu that
contains the parameter to be changed. Refer to Tables 6‐4 to 6‐12 for the
motor drive parameters and their factory default values.
3. Press the Enter button.
4. Rotate the jog dial clockwise until the display shows the parameter to be
changed.
5. Press the Enter button again to open the parameter.
6. If needed, rotate the jog dial again until the display shows the
sub‐parameter to be changed, and press the Enter button.
NOTE: Press ESC at any time to move backwards through the menus.
7. Rotate the jog dial clockwise or counterclockwise until the display shows
the desired value for the parameter.
8. Press the Enter button to store the value
9. Press ESC to exit the parameter and, if needed, again to exit the
sub‐parameter.
10. Press ESC to exit the menu.
11. Repeat steps 2.-10. as needed until all parameters are set to the factory
default values shown in Tables 6‐4 to 6‐12.
12. Press ESC to until the display shows rdy.