Operating Parameters
B-10
Part 1107600_03
2014 Nordson Corporation
Temperature Control (contd)
26
Manual Standby Time
Description:
The amount of time that the melter will remain in the standby mode after
the standby key is pressed.
Value:
0 to 180 minutes
Resolution:
1 minute
Default Value:
0
Format:
Use:
Set the standby time when you want the operator to be able to place the
melter into the standby mode for a limited period of time (break, lunch,
etc.). When manual standby is enabled (value greater than 0 minutes),
the standby LED blinks.
Set the standby delta (parameter 23) to the desired value before setting
parameter 26.
Note: When a time value equal to or greater than 1 minute is entered, the
standby LED will flash to indicate that the manual standby timer is
counting down.
27
Hose Standby Delta
Description:
The number of degrees by which all heated hoses will be decreased
when the applicator is placed into the standby mode.
Value:
1 C to 190 C (1 F to 350 F)
Resolution:
1 C
1 F
Default Value:
0
Format:
Use:
This parameter functions like parameter 23 except when it is set to 0, in
which case it reverts to the setting for parameter 23.
NOTE: The standby delta does not affect the under temperature delta
(parameter 22).
28
Gun Standby Delta
Description:
The number of degrees by which all heated guns will be decreased when
the applicator is placed into the standby mode.
Value:
1 C to 190 C (1 F to 350 F)
Resolution:
1 C
1 F
Default Value:
0
Format:
Use:
This parameter functions like parameter 23 except when it is set to 0, in
which case it reverts to the setting for parameter 23.
NOTE: The standby delta does not affect the under temperature delta
(parameter 22).