Operating Parameters
B-11
Part 1107600_03
2014 Nordson Corporation
29
Internal Zone Temperature Offset
Description:
The difference in the number of degrees by which the melter’s internal
zones will operate. If this parameter is used, the primary internal zone will
operate at a lower temperature than the secondary internal zone as
determined by the value of this parameter.
Value:
0 C to -15 C (0 F to -30 F)
Resolution:
1 C
1 F
Default Value:
0
Format:
Use:
Melter internal zones are designated as follows:
DuraBlue D10/D16: primary=tank; secondary=pump
DuraBlue D4L/D10L/D16L: primary=tank; secondary=pump
AltaBlue TT: primary=tank; secondary=pump
DuraBlue 25/50/100: primary=grid; secondary=reservoir
AltaBlue 15/30/50/100: primary=grid; secondary=reservoir
DuraDrum: primary=platen; secondary=pump