Installation
3-22
Part 1107600_03
2014 Nordson Corporation
To read or edit a parameter (contd)
Table 3‐5 Operating Parameters
Parameter Name Range of Values Default Value
Standard
0 Enter Password 0 to 9999 4000
1 Total Hours with Heaters On (noneditable) 0 to 9999 0
2 Fault Log (noneditable) — _-F0 (empty)
3 Change History Log (noneditable) — P-_ (empty)
4 Ready Delay Time 0 to 60 minutes 0 minutes
5 Service Interval Time 0 to 8736 hours 500 hours
6 Service LED Heater Hours 0 to 9999 hours 0
7 Motor Off Delay 0 to 360 seconds 0 seconds
8 Automatic Pump On 0 (disabled) or 1 (enabled) 1 (enabled)
10 Enable or Disable Password 0 (disabled) or 1 (enabled) 0 (disabled)
11 Create Password 0 to 9999 5000
12
Change Hose 1 Output to Electric Gun
Activation
0 (disabled) or 1 (enabled) 0 (disabled)
13
Change Hose 2 Output to Electric Gun
Activation
0 (disabled) or 1 (enabled) 0 (disabled)
14 External Communications Lock-out 0 or 1 0 (disabled)
Temperature Control
20
Temperature Units (degrees C or F)
C (degrees Celsius) or F (degrees
Fahrenheit)
C (degrees Celsius)
21 Over Temperature Delta
5 C (10 F) to 60 C(110 F) 15 C (25 F)
22 Under Temperature Delta
5 C (10 F) to 60 C(110 F) 25 C (50 F)
23 Standby Delta
5 C (10 F) to 190 C (350 F) 50 C (100 F)
24 Automatic Standby Timeout 0 to 1440 minutes 0 (disabled)
25 Automatic Heaters Off Time 0 to 1440 minutes 0 (disabled)
26 Manual Standby Time 0 to 180 minutes 0 (disabled)
27 Hose Standby Delta
1 C (1 F) to 190 C (350 F)
0 (disabled)
28 Gun Standby Delta
1 C (1 F) to 190 C (350 F)
0 (disabled)
29 Internal Zone Temperate Offset
0 C (0 F) to -15 C (-30 F)
0 (disabled)
Input Setup
34 Optional Input 5 0−9, 11, and 13−14 0 (disabled)
35 Optional Input 6 0−9, 11, and 13−14 0 (disabled)
36 Optional Input 7 0−9, 11, and 13−14 0 (disabled)
37 Optional Input 8 0−9, 11, and 13−14 0 (disabled)
38 Optional Input 9 0−9, 11, and 13−14 0 (disabled)
39 Optional Input 10 0−9, 11, and 13−14 0 (disabled)
Continued...