Melter control switch (A4)
Heaters LED
Automatic scan sequence
Ready LED
Pump speed arrow keys
Operation
4-5
Part 1107600_03
2014 Nordson Corporation
To start the melter
1. Switch the melter on.
The melter:
Tests the control panel LEDs
Turns on the heaters (the heaters LED turns green)
Begins to automatically scan through and display the
actual temperature of the tank and each hose and gun that has a
setpoint temperature that is greater than zero degrees. The sequence
of the automatic scan is: tank, each hose and gun pair, and then back
to the tank.
Turns on the ready LED (green) when the tank and all of the
hoses and guns are within 3 C (5 F) of their assigned
setpoint temperature.
2. Press the pump speed arrow keys to adjust the motor to the lowest rpm.
The current motor speed is indicated on the display.
NOTE: Each press of an arrow key increases/decreases the motor
speed by 1 rpm (factory default).