Maintenance
5-8
Part 1089210A04
E 2010 Nordson Corporation
Reflector Replacement (contd)
Focus Reflector Curve and Retaining Bracket Installing the Focus Retaining Bracket
Figure 5-7 Focus Reflector Installation
Flood Reflectors: See Figure 5-8. The edge of the reflector will sit on
the retainer springs on the inside edge of the bracket.
The lip on the flood bracket will go to the inside of the lamphead and
wrap around the edge of the reflector. The curve of the reflector causes
the reflector to sit farther away from the side of the lamphead. Line up
the retaining bracket mounting holes with the mounting holes in the
lamphead base.
Flood Reflector Curve and Retaining Bracket
Installing the Flood Retaining Bracket
Figure 5-8 Flood Reflector Installation
8. Install the six mounting screws to secure the reflectors and retaining
brackets. Torque the screws to 1.81.57 NSm (0.871.16 lb-ft).
9. Install the bulb and RF screen as described in Bulb Replacement.