EasyManua.ls Logo

Nordson DuraBlue II - Page 173

Nordson DuraBlue II
206 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Calculating Melter Power Requirements
A-3
Part 1126931_01
2018 Nordson Corporation
Table A‐1 Hose/Applicator Wattages
Component
Number
Type/Size
A B C
Component
Wattage
Hose/Applicator
Pair Wattage
Two
Hose/Applicator
Pair Wattage
Hose 1
Applicator 1
Hose 2
Applicator 2
Hose 3
Applicator 3
Hose 4
Applicator 4
Hose 5
Applicator 5
Hose 6
Applicator 6
Table A‐2 Maximum Allowable Hose/Applicator Wattages
Column in
Table A‐1
Component Maximum Wattage
A Any single hose or applicator 1000 W
B Any hose/applicator pair 1200 W
C
Sum of hose/applicator pairs 1
and 2
2000 W
Sum of hose/applicator pairs 3
and 4
2000 W
D
Any single hose, or applicator 5
or 6
2000 W
E Hose/applicator pair 5 or 6 2000 W
F
Sum of hose/applicator pairs 5
and 6
4000 W
NOTE: Total external wattage must not exceed 8,000 W.

Table of Contents