Calculating Melter Power Requirements
A-3
Part 1126931_01
2018 Nordson Corporation
Table A‐1 Hose/Applicator Wattages
Component
Number
Type/Size
A B C
Component
Wattage
Hose/Applicator
Pair Wattage
Two
Hose/Applicator
Pair Wattage
Hose 1
Applicator 1
Hose 2
Applicator 2
Hose 3
Applicator 3
Hose 4
Applicator 4
Hose 5
Applicator 5
Hose 6
Applicator 6
Table A‐2 Maximum Allowable Hose/Applicator Wattages
Column in
Table A‐1
Component Maximum Wattage
A Any single hose or applicator 1000 W
B Any hose/applicator pair 1200 W
C
Sum of hose/applicator pairs 1
and 2
2000 W
Sum of hose/applicator pairs 3
and 4
2000 W
D
Any single hose, or applicator 5
or 6
2000 W
E Hose/applicator pair 5 or 6 2000 W
F
Sum of hose/applicator pairs 5
and 6
4000 W
NOTE: Total external wattage must not exceed 8,000 W.