Operating Parameters
B-3
Part 1126931_01
2018 Nordson Corporation
3 Change History Log (Noneditable)
Description:
Records the last ten changes made to either the set‐point temperatures or the
operating parameters.
Value:
Resolution:
Default Value:
P‐_ (unused log entry)
Format:
Refer to Section 3, Installation. Review Parameter and Set‐point Temperature
Changes.
Use:
Use the right‐display key to review the log entries for the last ten changes that
were made to the operating parameters or the set‐point temperatures. Empty log
entries are indicated by “P‐_.”
4 Ready Delay Time
Description:
The amount of time that will elapse after all of the components have reached
their set‐point temperature before the ready LED will turn on. The ready delay
time only functions when the temperature of the tank, at the time the melter is
turned on, is more than 27 C (50 F) from its set‐point temperature. The ready
delay time begins when all components are within 3 C (5 F) of their respective
set‐point temperature.
Value:
0 to 60 minutes
Resolution:
1 minute
Default Value:
0 minutes
Format:
Use:
The ready delay allows the contents of the tank an additional amount of time to
heat before pump turns on.
NOTE: The time remaining on the ready delay is indicated in minutes in the right
display at the end of every automatic scan cycle. When the delay time reaches 1
minute, the time remaining appears in seconds.
5
Service Interval Time
Description:
The number of heater‐on hours that must elapse before the service LED turns
on.
Value:
0 hours (disabled) to 8736 (one year)
Resolution:
1 hour
Default Value:
500 hours
Format:
Use:
Set the service interval time to signal a user‐defined service check or
maintenance event, such as changing the filter. The service LED will turn on
after the pre‐set time elapses. With the melter in the scan mode, press the
Clear/Reset key to turn off the service LED and reset the time.