Operating Parameters
B-4
Part 1126931_01
2018 Nordson Corporation
Standard (contd)
6
Service LED Heater Hours
Description:
A timer indicates how many more hours the heaters need to remain on before
the service LED illuminates (service required).
Value:
0 hours (disabled) to 9999
Resolution:
1 hour
Default Value:
0
Format:
Use:
The service interval time (parameter 5) must be enabled before this parameter
will work.
Note: Heater hours accumulate whenever the heaters LED is illuminated.
7 Motor Off Delay
Description:
Not being used, only displayed.
10
Enable or Disable the Melter Password
Description:
Activates or deactivates the melter password. When password protection is
activated, component set‐point temperatures or melter operating parameters
cannot be changed until a valid password is entered using parameter 0.
Value:
0 (disabled)
1 (enabled)
Resolution:
Default Value:
0
Format:
Use:
A password must first be created using parameter 11 before it can be enabled or
disabled using parameter 10.
11
Create Password
Description:
A user‐defined password that prevents unauthorized changes to operating
parameters or set‐point temperatures.
Value:
0 to 9999
Resolution:
1
Default Value:
5000
Format:
Use:
Refer to Section 4, Operation, Enter Password.
NOTE: When the password is created and enabled, parameter 10 will not
appear again in the right display until the password is entered.