Operating Parameters
B-5
Part 1126931_01
2018 Nordson Corporation
20 Temperature Units
Description:
Sets the units for temperature display.
Value:
C (degrees Celsius) or F (degrees Fahrenheit)
Resolution:
0 = Celsius
1 = Fahrenheit
Default Value:
0
Format:
—
Use:
—
21
Over Temperature Delta
Description:
The number of degrees that the temperature of any component can increase
over its assigned set‐point temperature before an over temperature fault (F3) will
occur.
Value:
5 C (10 F) to 60 C (110 F)
Resolution:
1C
1F
Default Value:
15 C (25 F)
Format:
—
Use:
—
22
Under Temperature Delta
Description:
The number of degrees that the temperature of any component can decrease
from its set‐point temperature before an under temperature fault (F2) occurs.
Value:
5 C (10 F) to 60 C (110 F)
Resolution:
1C
1F
Default Value:
25 C (50 F)
Format:
—
Use:
—