Melter Communications
C-9
Part 1126931_01
2018 Nordson Corporation
To upgrade or reload melter firmware (contd)
CAUTION! Once the uprade progress bar appears, do not interrupt the
upgrade process for any reason. Interupting the upgrade can corrupt the
melter's firmware, which will require replacement of the IC chip
(IC service kit P/N 1018817).
10. Click OK.
The communications link between the melter and the PC is terminated.
11. Do one of the following:
To restore pre‐upgrade melter settings, go to To restore pre‐upgrade
melter settings.
To close the NCM, click Exit.
To restore melter settings other than the settings that were in use by
the melter before the upgrade, go to Saving and Restoring Melter
Settings earlier in this guide.
To restore pre‐upgrade melter settings
1. Place the melter into the configuration mode by simultaneously pressing
the Standby and Setup keys.
COnF” appears in the right display.
2. Click Connect.
The Select COM Port dialog box appears.
3. Select the COM port you are using to connect to the melter, and then
click Ok.
The PC and melter establish communications and a picture of the melter
you selected appears in the device status area. The right side of the
status area indicates “CONNECTED”.
4. Click Restore Pre‐Upgrade Settings.
The pre‐upgrade settings are restored and the melter returns to the scan
mode.
5. Click Exit to close the NCM.