Flushing the Gun
The entire hot melt application system, including the gun, must be flushed
after installing a new gun. Flushing removes excess dirt and charred
material from the applicator system and purges any Type R fluid left over in
the gun from factory testing.
CAUTION: Hot! Risk of burns. Hot applicator parts, splashed hot melt
material, and hot gun surfaces can cause severe burns. Wear long‐sleeved,
heat‐protective clothing, safety goggles, and heat‐protective gloves.
WARNING: Risk of burns. System or material pressurized. Airtrapped in
the hose or gun can spit out molten adhesive that can cause severe burns.
Failure to relieve hydraulic pressure can result in serious burns. Relieve
pressure.