iCare+ Operation Manual 10-8-1 p. 32
ENGLISH
4.2.5. Replacing the junction support blister
The blister allows the collecting of the possible drops of products during its change; it had to be replaced
periodically.
As mentioned in the part 4.1. General cleaning guidelines, the frequency of replacement of the support junction
blister is 1 year.
First of all, open the top cover of iCare+ device to remove the soiled blister (see Figure 28), and then put directly the
new one on the support junction (by being sure that this last is properly sealed by means of the new blister).
CAUTION: When removing the soiled blister, do not empty out the used products on
the iCare+ device, on the surface of its and on the floor.
4.2.6. Replacing the o-ring joints of E-type connector
Press the o-ring joint and remove it from the E-type connector (see Figure 29).
Thread the new o-ring joints in the corresponding grooves.
Figure 28: Replacement of the junction support blister
Figure 29: O-ring joints of E-type connector