The response to the NXP_FELICA_RAW command is as follows:
Table 95. FeliCa Raw Response parameters
Description Length
Status 1
Data N
Status: bits b0 to b2 indicate information on valid bits in the last data byte (value 0
indicates all are valid, from 1 to 7 it indicated the number of valid bits.
Data is the raw frame received from the card.
Note:
As FeliCa operates with full bytes, Status byte of NXP_FELICA_RAW command
value should be 0x00.
Table 96. NXP_FELICA_CMD Command
Value Command Description
’21’
NXP_FELICA_CMD
This command allows the exchange of data between the
host and a FeliCa card previously activated.
This command has the following parameters:
Table 97. NXP_FELICA_CMD Parameters
Description Length
Cmd 1
Data N
Cmd describe the FeliCa
command type
Table 98. FeliCa Command Description
Value Description
0x00 Check
0x01 Update
others RFU
Data is an array containing the data to be sent within the command as follows:
Check command: