9.5 SWP
The host can manage the secure element connected over SWP through a dedicated gate
“SWPMgt”.
Table 58. SWP Management Gate
Gate G
ID
SwpMgt gate ‘A0’
Using this gate the host is able to:
Activate/Deactivate SWP link
Get information on SWP link status
Table 59. SWP Events
Value Event Description
‘03’
NXP_EVT_SWP_SWITCH_MODE
This event is sent by the host to temporary
activate/deactivate SWP link.
Warning:
PN544 cannot go back to Standby
mode if ‘Default mode’ is not set.
It means that ‘Off mode’ & ‘On mode’ will
keep PN544 in ActiveBAT.
‘04’
NXP_EVT_SWP_PROTECTED
This event is sent to the host, when protected
mode has been enabled (see related
NXP_SWP_PROTECTION_MODE registry
entry), to inform a RF-SWP transaction has
been blocked.
The NXP_EVT_SWP_SWITCH_MODE event has parameters as follows
Table 60. SWP Switch Mode Event
Description Length
Mode 1