The response to the NXP_WR_ACTIVATE_NEXT command is as follows:
Table 122. NXP_WR_ACTIVATE_NEXT Response
Description Length
Status 1
Status field indicates if the activation has been successful
Table 123. NXP_WR_ACTIVATE_NEXT Response Description
Value Description
0x00 Single target in the field
0x03 Several targets in the field
The NXP_WR_ACTIVATE_ID command has the following parameters:
Table 124. NXP_WR_ACTIVATE_ID Command
Description Length
ID N
ID value specify ID of the remote card to activate:
- Type A Reader RF gate: UID
- Type B Reader RF gate: PUPI
- Type F Reader RF gate: IDm
(Jewel RF reader gate does not allow multiple activation)
The NXP_WR_DISPATCH_TO_UICC command has the following parameters:
Table 125. NXP_WR_DISPATCH_TO_UICC Command
Description Length
ID N
ID value specify ID of the remote card to activate:
- Type A Reader RF gate: UID
- Type B Reader RF gate: PUPI