EasyManua.ls Logo

Omron CP1E CPU UNIT SOFTWARE - Page 195

Omron CP1E CPU UNIT SOFTWARE
450 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12-27
12 Pulse Outputs
CP1E CPU Unit Software User’s Manual(W480)
12-4 Defining Origin Position
12
12-4-5 Origin Search Operations
Origin Detection Method 0: Origin Proximity Input Signal Reversal Required
(Recommended Method)
Origin Detection Method 1: Origin Proximity Input Signal Reversal Not
Required
Origin Detection Method 2: Origin Proximity Input Signal Not Used
Origin Detection Method Setting
1
0
1
0
CCW CW
Origin Proximity
Input Signal
Origin Input Signal
Pulse output
Deceleration starts when Origin
Proximity Input Signal turns ON.
After the Origin Proximity Input Signal turns
ON and then OFF, the motor is stopped
when the Origin Input Signal turns ON.
Initial speed
Acceleration
High speed for origin search
Deceleration
Proximity speed for origin search
Start when ORG is executed Stop
1
0
1
0
CCW CW
Origin Proximity
Input Signal
Origin Input Signal
Pulse output
Deceleration starts when Origin
Proximity Input Signal turns ON.
Initial speed
Acceleration
High speed for origin search
Deceleration
Proximity speed for origin search
Start when ORG is executed
Stop
After the Origin Proximity Input Signal turns
ON, the motor is stopped when the Origin
Input Signal turns ON.
1
0
Origin Input Signal
Pulse output
Initial speed
Acceleration
Start when ORG is executed Stop
Proximity speed
for origin search
The motor is stopped when the
Origin Input Signal turns ON.

Table of Contents

Related product manuals