6. Tighten the line set screws for each line in the connector. Tighten the
screws to a torque of 0.25 to 0.3 N
m.
You will not be able to tighten these screws with a normal screwdriver,
which narrows to a point at the end. You will need a screwdriver that is con-
sistently thin for the entire length.
Crimp Terminals
We recommend the following crimp terminals.
Phoenix Contact, AI-series Crimp Terminals
Insert the line into the terminal and then crimp.
The following crimp tool is also available.
Phoenix Contact, ZA3 Crimp Tool
The OMRON XW4Z-00C Screwdriver is available for tightening the line set
screws. The end of the screwdriver has the following dimensions.
Supplying Communications Power Using T-branch Taps
Connect the V+ and V– of the power lines to the connectors in the same
way as for the communications cables. If the communications power sup-
Use a flat-blade screwdriver that is
consistently thin at the end.
Connector without Set Screws
Crimp
terminal
Wire
Side View Front View
0.6 mm 3.5 mm