EasyManua.ls Logo

Omron STC-MBS122BPOE

Omron STC-MBS122BPOE
73 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
No.19S207-00
36/73
STC-MBS122BPOE / STC-MCS122BPOE
Product Specifications and User’s Guide
10 Camera Functions
10.1 Save and load the camera settings
The camera has the camera setting save function, and camera setting including factory default loads
function.
The camera has below two type of camera settings.
Default: The factory default settings (This setting cannot change)
UserSet X: Over writeable camera settings (X: 0 to 7)
These camera settings load from ROM to register in RAM on camera, and camera settings at register in RAM
on camera save to ROM.
The camera settings saving and loading are controllable with Parameters (“UserSetSelector”,
“UserSetDefault”), and commands (“UserSetLoad”, “UserSetSave”) in “UserSetControl” category of
GenICam.
The details of the parameters and the functions are in the table below:
GenICam Parameters
UserSetSelector
IEnumeration Type
Select “Default” or ”UserSet X”
“UserSetLoad” or “UserSetSave” process for selected settings.
UserSetLoad
ICommand Type
The camera settings load from ROM to register in RAM.
UserSetSave
ICommand Type
The camera settings at register in RAM save to ROM.
UserSetDefault
IEnumeration Type
Select which settings (“Default” or “UserSet X”) load automatically when
camera power is on. This selection saves automatically.
Saving Camera Settings
Setting Procedure
1. Selects “UserSet X” at “UserSetSelector
2. Execute “UserSetSave”
When executing “UserSetSave”,
camera settings at the register in RAM are
saved to the ROM that is selected at
“UserSetSelector”.
Caution:
“UserSetSave” CANNOT execute when
“Default” was selected at “UserSetSelector”
ROM
UserSet 0 to 7
ROM
Default
Camera
Settings
UserSetSelector
Selector

Table of Contents