AGC (Auto Gain Contorl)
The brightness of image maintains to keep target brightness with gain automatically.
If the brightness of image is darker than target brightness, gain increases up to “GainAutoLimitMax”.
If the brightness of image is brighter than target brightness, gain decreases.
GenICam Parameters
GainSelector
IEnumeration Type
Adjustable gain selection
Selected gain can be adjusting by Gain[GainSelector].
Please select “AnalogAll” when AGC is turned on.
Selection: “AnalogAll” (analog gain) and “DigitalAll” (digital gain)
Default: “AnalogAll”
Gain[GainSelector]
IFloat Type
Gain
Selected gain at “GainSelector” is adjusting
Analog gain:
Range: 0 to 208
Default: 0
Digital gain:
Range: 0 to 255
Default: 0
Analog gain cannot adjustable when AGC is turned on.
GainAuto
[GainSelector]
IEnumeration Type
AGC ON / OFF selection
Selection: “ON” (Continuous) and “OFF” (Off)
Default: OFF
GainAutoLimitMin
[GainSelector]
IFloat Type
Minimum gain for AGC
Range: 0 to 208
Default: 0
This cannot be set greater than “GainAutoLimitMax”
GainAutoLimitMax
[GainSelector]
IFloat Type
Maximum gain for AGC
Range: 0 to 208
Default: 208
This cannot be set smaller than “GainAutoLimitMin”