No.19S207-00
58/73
STC-MBS122BPOE / STC-MCS122BPOE
Product Specifications and User’s Guide
3) How to use PTP
Selects “True” at GevIEEE1588 then synchronize camera time to “Master Clock” (synchronize time
is different depending on system). The camera is ready for action command after synchronize to
“Master Clock”.
4) Synchronized exposure for trigger mode
When action command generating, action command is broadcasting to each camera and camera starts
exposing.
Synchronized exposure does not secure if action command does NOT include Timestamp. If action
command includes Timestamp, action command will be scheduled automatically and each camera start
exposing at same time.
ActionControl setting is required when action command generating.
IEEE1588
PTP supported
Switching HUB
PC
M
S S S S S
M: Master
S: Slave
S
e.g. PTP configuration