137
Address Instruction Data
0000 LD 0100
0001 AND 0101
0002 LD 0201
0003 AND NOT 0102
0004 OR LD
0005 AND 0103
0006 AND NOT 0104
0007 OUT 0201
0008 END(01)
Before Insertion
Address Instruction Data
0000 LD 0100
0001 AND 0101
0002 LD 0201
0003 AND NOT 0102
0004 OR LD
0005 AND 0103
0006 AND 0105
0007 AND NOT 0104
0008 OUT 0201
0009 END(01)
Address Instruction Data
0000 LD 0100
0001 AND NOT 0101
0002 LD 0201
0003 AND NOT 0102
0004 OR LD
0005 AND 0103
0006 AND 0105
0007 AND NOT 0104
0008 OUT 0201
After Insertion After Deletion
The following key inputs and displays show the procedure for achieving the
program changes shown above.