Section 5 V680S Command Details
ď‚§ Execution Example
Copying Four Words of Data Starting from Word Address 1234 Hex in the RF Tag to an RF Tag in the
Communications Field of the Reader/Writer with IP Address 192.168.1.201 (C0A801C9 Hex)
The operation indicator on the copy source Reader/Writer will change as shown in the following table.
To check the communications diagnostics result of the copy destination Reader/Writer, use the Web server function to
check the copy destination Reader/Writer separately.
Refer to Web Server in Section 2 Names and Functions of Components for detailed information on Web server function.
p.43
Copy destination
Communications
normal (stable
communications):
Indicator lights green.
Communications
normal (unstable
communications):
Indicator lights yellow.
Communications failed:
Indicator lights red.
Copy source
Communications
normal (stable
communications):
Indicator lights green.
Communications
normal (stable
communications):
Indicator lights green.
Communications
normal (unstable
communications):
Indicator lights yellow.
Communications failed:
Indicator lights red.
Communications
normal (unstable
communications):
Indicator lights yellow.
Communications
normal (unstable
communications):
Indicator lights yellow.
Communications
normal (unstable
communications):
Indicator lights yellow.
Communications failed:
Indicator lights red.
Communications failed:
Indicator lights red.
Communications failed:
Indicator lights red.
Communications failed:
Indicator lights red.
Communications failed:
Indicator lights red.
CmdCode
CmdParam1
CmdParam2
Data name
+1
Memory offset
ErrCode
RespInfo1
RespInfo2
Data name
+1
+2
+3
Memory offset
Command Area Response Area
bit15-12 bit11-8 bit7-4 bit3-0
0
000
0
000
0000
bit15-12 bit11-8 bit7-4 bit3-0
0
008
1
234
0004
0
1C9
C0A8
CmdData[0-1]
CmdData[2-3]
RF Tag Memory in the Copy Destination Reader/Writer
+2
+3
+4
+5
bit15-12 bit11-8 bit7-4 bit3-0
1
122
3
344
5566
1234
Hex
1235Hex
1236Hex
User address
77881235Hex
RF Tag Memory in the Copy Source Reader/Writer
bit15-12 bit11-8 bit7-4 bit3-0
1
122
3
344
5566
1234
Hex
1235Hex
1236Hex
User address
77881235Hex

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron V680S Series and is the answer not in the manual?

Omron V680S Series Specifications

General IconGeneral
BrandOmron
ModelV680S Series
CategoryRfid Systems
LanguageEnglish

Related product manuals