EasyManuals Logo

Omron V680S Series User Manual

Omron V680S Series
300 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #124 background imageLoading...
Page #124 background image
Section 5 V680S Command Details
COPY DATA
This command uses two Reader/Writers to copy data from an RF Tag in the communications field of
one Reader/Writer (A) to the RF Tag in the communications field of another Reader/Writer (B).
Command Area
Response Area
Signal/data Data type Size Function
CmdCode/Command Code WORD 2 bytes 0008 hex
CmdParam1/Command Parameter
1
WORD 2 bytes
First word address of the data to copy from the RF Tag
0000 to FFFF hex
CmdParam2/Command Parameter
2
WORD 2 bytes
Number of words in the RF Tag to copy
0001 to 0200 hex
CmdData/Command Data
IP address
DWORD 4 bytes
IP address of Reader/Writer at the copy destination
0000 0000 to FFFF FFFF hex
Example: C0A801C8 hex (192.168.1.200)
Signal/data Data type Size Function
ErrCode/Error Code WORD 2 bytes Error code
RespInfo1/Response Information 1 WORD 2 bytes Device information
RespInfo2/Response Information 2 WORD 2 bytes Communications diagnostics result
Copy Source
Reader/Writer
Switching Hub
PLC
Copy Destination
Reader/Writer