Section 5 V680S Command Details
COPY DATA
This command uses two Reader/Writers to copy data from an RF Tag in the communications field of
one Reader/Writer (A) to the RF Tag in the communications field of another Reader/Writer (B).
Command Area
Response Area
Signal/data Data type Size Function
CmdCode/Command Code WORD 2 bytes 0008 hex
CmdParam1/Command Parameter
1
WORD 2 bytes
First word address of the data to copy from the RF Tag
0000 to FFFF hex
CmdParam2/Command Parameter
2
WORD 2 bytes
Number of words in the RF Tag to copy
0001 to 0200 hex
CmdData/Command Data
IP address
DWORD 4 bytes
IP address of Reader/Writer at the copy destination
0000 0000 to FFFF FFFF hex
Example: C0A801C8 hex (192.168.1.200)
Signal/data Data type Size Function
ErrCode/Error Code WORD 2 bytes Error code
RespInfo1/Response Information 1 WORD 2 bytes Device information
RespInfo2/Response Information 2 WORD 2 bytes Communications diagnostics result
Copy Source
Reader/Writer
Switching Hub
PLC
Copy Destination
Reader/Writer