INITIALIZE
This command restores the Reader/Writer settings to their default values.
Command Area
Response Area
Execution Example
Initializing All Settings
Signal/data Data type Size Function
CmdCode/Command Code WORD 2 bytes 1000 hex
CmdParam1/Command Parameter 1 WORD 2 bytes 0000 hex (Not used.)
CmdParam2/Command Parameter 2 WORD 2 bytes 0000 hex (Not used.)
Signal/data Data type Size Function
ErrCode/Error Code WORD 2 bytes Error code
RespInfo1/Response Information 1 WORD 2 bytes 0000 hex (Not used.)
RespInfo2/Response Information 2 WORD 2 bytes 0000 hex (Not used.)
bit15-12 bit11-8 bit7-4 bit3-0
1
000
0
000
0000
CmdCode
CmdParam1
CmdParam2
Data name
+1
+2
+3
Memory offset
Command Area
ErrCode
RespInfo1
RespInfo2
Data name
+1
+2
+3
Memory offset
Response Area
bit15-12 bit11-8 bit7-4 bit3-0
0
000
0
000
0000