Section 5 V680S Command Details
ď‚§ Execution Example
Reading the Multi-Reader/Writer Settings When the Multi-Reader/Writer Mode Is Set to Field
Extension Mode, the Number of Slave Reader/Writers Is Set to 3, and the IP Addresses of Slaves No.
1, No. 2, and No. 3 Are Set to 192.168.1.201, 192.168.1.202, and 192.168.1.203, Respectively
bit15-12 bit11-8 bit7-4 bit3-0
1
004
0
000
0000
CmdCode
CmdParam1
CmdParam2
Data name
+1
+2
+3
Memory offset
Command Area
ErrCode
RespInfo1
RespInfo2
Data name
+1
+2
+3
Memory offset
Response Area
bit15-12 bit11-8 bit7-4 bit3-0
0
000
0
000
0000
0
100
0
300
0
1C9
C0A8
0 1CA
C
0A8
0
1CB
C0A8
0 000
0000
0 000
0
000
0
000
0000
0 000
0000
RespData[0-1]
RespData[2-3]
RespData[4-5]
RespData[6-7]
RespData[8-9]
RespData[10-11]
RespData[12-13]
RespData[14-15]
RespData[16-17]
RespData[18-19]
RespData[20-21]
RespData[22-23]
RespData[24-25]
RespData[26-27]
RespData[28-29]
RespData[30-31]
+4
+5
+6
+7
+8
+9
+10
+11
+12
+13
+14
+15
+16
+17
+18
+19
IP address of Slave Reader/Writer No. 1
IP address of Slave Reader/Writer No. 2
IP address of Slave Reader/Writer No. 2