Section 2 Using Multi-Reader/Writer Operation
Enabling Field Extension Mode
1. Connect all of the Reader/Writers with Ethernet Cables and turn ON the power supplies.
Set a unique IP address for each Reader/Writer in advance.
Refer to Section 4 Preparations for Communications.
2. Start a Web browser on your computer.
3. In the address field on the Web browser operation window, enter the IP address of the master Reader/
Writer (here, 192.168.1.200).
4. Display the RF Tag Communications Settings View, set the RF Tag communications option to Once or
Repeat, and then click the Set Button.
If you specify the FIFO Repeat communications option, multi-Reader/Writer operation will be enabled and a multi-
Reader/Writer execution error will occur when you restart.
http:// (IP address)