Chapter-11
Appendix
High Resolution Model (HD) Reading Characteristics
Code 39
GS1 DataBar
Composite Code
PDF417
QR Code
Data Matrix
: 0.076 mm
: 0.127 mm
: 0.127 mm
: 0.127 mm
: 0.127 mm
: 0.127 mm
OPTOELECTRONICS
test chart
Possible to read:
Width 80 mm Code 39 Resolution 0.2 mm
(DOF: 138 mm)
Possible to read:
UPC 100% moving at 2.54 m/s (DOC: 118 mm)
High Resolution Model (HD) Reading Depth of Field
* The depth of field is a determined while using the OPTOELECTRONICS test chart PCS 0.9, without specular
reflection and at room temperature and room humidity.
* Refer to 2.5.2 High Resolution Model (HD) Depth of Field for drawing.