EasyManua.ls Logo

Opticon NLV-5201 - Good Read Aiming

Opticon NLV-5201
172 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Chapter-4
Indicator Options
NLV-5201 User's Manual
44
1st
Good Read Aiming
4.3
The green aiming lights up after a code was successfully read.
Aiming indicator frequency and indicator durations after reading are configurable.
Item
Command
Function
Description
Default
Good Read
Aiming
[EF3
Qa
Qb
Qc
a
Setting
items
0:Indicator frequency
1:First indicator duration
after reading
b
Numerical
setting
10b + c
Indicator frequency
00-99 times
Indicator duration
00-99 x10 ms
Indicator
frequency 0 time
Indicator duration
50 ms
c
Setting example)
- Lights 2 times (After 100 ms: Default)
Command: [EF3Q0Q0Q2
- Set first indicator duration after reading to 500 ms
Continue to above indicator frequency setting
Command: [EF3Q1Q5Q0

Table of Contents

Other manuals for Opticon NLV-5201