Powering On a Controller
by the total number of disk shelves in the cabinet. At full load, each Sun Disk Shelf draws
912W.
■
The power source must provide a reliable earth connection for each disk shelf and the
cabinet.
■
The power source must be easily accessible because the power cord is the main disconnect
device for the disk shelf.
1.
Plug the two power cords into the universal power connectors.
2.
Connect the cords to the external power source.
3.
Turn on the disk shelf power switches.
4.
Wait several minutes until the power indicators are lit a steady green.
Related Topics
■
“Powering Off a Disk Shelf” on page 180
■
“Powering Off a Controller” on page 180
Powering On a Controller
Use the following procedure to power on an Oracle ZFS Storage Appliance controller.
1.
Plug power cables into power supply 0 and power supply 1 on the storage
controller(s).
2.
Connect cables to the external power source.
The controller automatically powers on.
3.
Wait until the Power/OK LED on the front panel next to the Power button lights
and remains lit (approximately two minutes).
If the Service Required amber indicator is lit, see “Using Oracle ILOM to Diagnose Hardware
Faults” in Oracle ZFS Storage Appliance Customer Service Manual. Also see the Oracle ILOM
documentation located in the documentation library for this software release at http://docs.
oracle.com/en/storage/.
Related Topics
■
“Powering Off a Controller” on page 180