INTRODUCTION
PACKETLIGHT NETWORKS PL-300 3.2 INSTALLATION AND CONFIGURATION MANUAL
CONFIDENTIAL AND PROPRIETARY INFORMATION. ALL RIGHTS RESERVED. PAGE 30
Parameter 88 Channels
Express Channel Link Loss (dB) ≤1.5
Operating Temperature (°C/°F) -20° to +85°C/-4° to +185°F
Connector Type Channels LC/UPC
Connector Type COM SC/UPC
1.6.4.3 DWDM Red/Blue MUX/DEMUX with Single Fiber Specifications
Table 13: DWDM Red/Blue MUX/DEMUX 100 GHz Single Fiber Specifications
Parameter Red Blue
Passband (Channels) CH21-CH36 CH45-CH60
Channel Spacing (GHz) 100 GHz 100 GHz
Link Loss (MUX+DEMUX) (dB) ≤3.5 ≤3.5
Adjacent Channel Isolation (dB) ≥26 ≥26
Non-Adjacent Channel Isolation (dB) ≥35 ≥35
Express Channel Wavelength (nm) 1491+/-6.5 1511+/-6.5
Express Channel Link Loss (dB) ≤1 ≤1
Connector Type Channels LC/UPC LC/UPC
Connector Type COM SC/UPC SC/UPC
Table 14: DWDM Red/Blue MUX/DEMUX 50 GHz Single Fiber Specifications
Parameter Red Blue
Passband (Channels) 15H-37C 40C–61H
Channel Spacing (GHz) 50 GHz 50 GHz
Link Loss (MUX+DEMUX) (dB) ≤3.5 ≤3.5
Adjacent Channel Isolation (dB) ≥26 ≥26
Non-Adjacent Channel Isolation (dB) ≥35 ≥35
Express Channel Wavelength (nm) 1491+/-6.5 1511 +/- 6.5
Express Channel Link Loss (dB) ≤1 ≤1
Connector Type Channels LC/UPC LC/UPC
Connector Type COM SC/UPC SC/UPC