109
DP-2330/3030
DEC 2004
Ver. 2.0
DP-2310/3010
046 On-Hook Time 0 = 0 sec.
~
90 = 90 sec.
Selects the on-hook time between sequential  
communication calls in 1 second step intervals.
047 Response Wait 
Interval
1 = 1 sec.
~
90 = 90 sec.
20 ~ 150 sec. 
(For France Only)
Selects the waiting interval for the response after 
completing the dialing.
048
~ 
049
Not Used
050 Ring Detect 
Mode
1 = Normal
2 = Rough
Selects the quality of ringer detection. Use if the line 
signal is out of regulation, set to "Rough" so that the 
unit may detect the ringing signals.
051 Not Used
052 Pulse Rate 1 = 10 pps
2 = 20 pps
Selects the dial pulse rate 10/20 pps.
053
~ 
054
Not Used
055 Busy Tone 
Check
1 = Off
2 = On
Selects whether to detect the Busy Tone.
056 Dial Tone Check
(Except for USA 
and Canada)
1 = Off
2 = On
Selects whether to detect Dial Tone before dialing 
the telephone number.
057 DC Loop Check
(Except for USA 
and Canada)
1 = Off
2 = On
Selects whether the unit checks the DC Loop during 
communication.
058 Comm. JRNL + 
Image
1 = Off (without image)
2 = On (with image)
Selects whether the machine prints the COMM. 
Journal with image.
059 Confidential 
RCV Report
1 = Off (does not print out)
2 = On (prints out)
Selects whether the machine prints the Confidential 
RCV Report.
060 Version Indicates the Host software 
version.
061 TX/RX/PRT/CPY 1 = Fax Transmit Count
2 = Fax Receive Count
3 = Total Count
4 = Copy Print Count
Displays the transmitted, received, total printed and 
copied document count.
062 Print Counter 1 = Off
2 = On
Selects whether to print in the Fax Parameter List, 
the counter information that is displayed in the 
Function Parameter No. 61.
063  
~ 
067
Not Used
Function Parameter Table
No. Parameter Selections Function