Description Specifies the user ID for the Auto-Configuration Server for using
TR-069.
Value Range Max. 255 characters (except ", &, ', :, <, >, and space)
Default Value Empty string
Web User Interface Reference Authentication ID (Page 149)
ACS_PASS
Value Format String
Description Specifies the user password for the Auto-Configuration
Server for using
TR-069.
Value Range Max. 255 characters (except ", &, ', :, <, >, and space)
Default Value Empty string
Web User Interface Reference Authentication Password (Page 149)
PERIODIC_INFORM_ENABLE
Value Format Boolean
Description Specifies whether or not the CPE (Customer Premises Equipment)
must
periodically send CPE information to the ACS (Auto-Configuration
Server) using the Inform method call.
Value Range
• Y (Enable)
• N (Disable)
Default Value
N
PERIODIC_INFORM_INTERVAL
Value Format Integer
Description Specifies the interval length, in seconds, when the CPE must attempt
to connect with the ACS and call the Inform method.
Note
• This setting is available only when
"PERIODIC_INFORM_ENABLE" is set to "Y".
Value Range 30–2419200
Default Value 86400
PERIODIC_INFORM_TIME
Value Format String
Document Version 2012-02 Administrator Guide 183