1.6 Function (Full-closed control)
Positive/negative direction over-travel inhibition, External latch signal, Near home
position, etc.
Positioning completion etc.
Primary delay filter or FIR type filter is adaptable to the command input
1/40 to 125200 times
Although the ratio of encoder pulse (numerator) and external scale pulse
(denominator) can be set anywhere between the range of 1 and 2
23
for the numerator
and 1 to 2
23
for the denominator, please use within the range indicated above.
Available (Up to 3 frequency settings can be used simultaneously.)
Model-type damping filter
Available (speed, torque)
Load variation suppression function
3rd gain switching function
Friction torque compensation
Hybrid vibration damping function
Quadrant projection suppression function
Two-degree-of-freedom control mode
Available (standard type)
Torque limit switching function
Motor working range setting function
Torque saturation protection function
Single-turn absolute function
Infinitely rotation absolute function
External scale position information monitor
function under semi-closed control