9.1List of parameters
9-9
9.1.4 Class 3: Velocity/ Torque/ Full-closed control
Set the acceleration processing time
in response to the velocity
instruction input.
Set the deceleration processing time
in response to the velocity
instruction input.
Sigmoid
acceleration/
deceleration time
setup
Set the S-curve time for
acceleration/deceleration process
when the velocity instruction is
applied.
Select the type of external scale.
0: A,B phase output type
1: Serial communication type
(incremental specification)
2: Serial communication type
(absolute specification)
3 to 6: For manufacturer’s use
Numerator of
external scale
division
Set up the numerator of the external
scale dividing setup.
When the set value = 0, the
operation is performed with the
encoder resolution used as the
division numerator.
Denominator of
external scale
division
Set up the numerator of the external
scale dividing setup.
Reversal of
direction of external
scale
When the set value = 0, the
operation is performed with the
encoder resolution used as the
division numerator.
External scale Z
phase
disconnection
detection disable
Validate/Invalidate Z-phase
disconnection detection when using
AB phase output type external
scale.
0: Valid
1: Invalid
Hybrid deviation
excess setup
Set the threshold of Err.25.0 (Hybrid
deviation excess error protection).
Hybrid deviation
clear setup
Clear hybrid deviation of each
revolution setting to zero.