1.7Function (Common)
1-11
1.7 Function (Common)
Applicable scaling ratio: 1/1000–8000
The electronic gear ratio is limited by the combination of communication cycle, PDO
size, and electronic gear ratio. For details, refer to "TECHNICAL REFERENCE
EtherCAT Communication Specification (SX-DSV03456)".
The load inertia is identified in real time by the driving state of the motor operating
according to the command given by the controller or setup support software
PANATERM for Multi.
The gain is set automatically in accordance with the rigidity setting.
Available (5 filters available)
Position comparison output function
Available
[Requirement]
EtherCAT communication is established.
Return to origin operation completed if in incremental mode.
Other than Countinuous rotating absolute mode (Pr0.15=4)
Overvoltage, undervoltage, overspeed, overload, overheat, overcurrent, encoder
failure, positional overdeviaition, EEPROM failure, etc.
Deterioration diagnosis function