11-9
11.4.2 Regenerative control function
This section describes the parameters of the power supply module that are related to the regeneration
control function.
For details on the specifications of the regenerative resistor, refer to "REFERENCE SPECIFICATIONS
Power supply module section (SX-DSV03452)".
Relevant parameters
PSM
Pr.
Name
Setting
range
Shipping
setting
Unit
Content
00
Regenerative
operation setup
0 to 3
1
-
Sets up the regeneration operation.
0: To be used by the manufacturer (do not set up the value)
1: An external resistor is used to execute regenerative overload
protection.
2: An external resistor is used, but regenerative overload protection is not
executed.
3: Driver is used without regenerative resistor, and regenerative overload
protection is not executed.
01
Regenerative
resistor load
factor selection
0 to 4
0
-
Selects the operation method for the regenerative resistor load factor
when an external regenerative resistor is selected (PSM Pr.00 = 1, 2).
0: Regenerative overload protection is detected with the regenerative
resistor operation rate of 10%.
1 to 4: To be used by the manufacturer (do not set up the values)
11.4.3 Main power off detection function
This section describes the parameters that are related to main power off detection.
For specifications of the main power supply, refer to "REFERENCE SPECIFICATIONS Power supply
module section (SX-DSV03452)".
PSM
Pr.
Name
Setting
range
Shipping
setting
Unit
Content
02
Main power off
detection time
0 to 2000
70
ms
Sets up the main power off detection time.
Main power off is not detected if the setting value is set smaller than 20 or
is set to 2000.
03
Main power off
warning
detection time
0 to 2000
0
ms
Sets the main power off warning detection time.
The main power off warning is not detected when the setting value is
smaller than 10 or is set to 2000.