Interface Specifications
2-16
2.4.2.2 Reallocation of input signal
To change the allocation of output signal, change the following parameters.
Relevant parameters
Class
No.
Attribute
Parameter
name
Unit
Range
Function
4
10
C
S
SO1 output
selection
-
-2147483648
to
2147483647
Assign functions to SO1 outputs.
These parameters are presented in hexadecimals.
Hexadecimal presentation is followed by a specific control mode
designation.
n 0 * * h: position/full-closed control
n 0 * * h: velocity control
n 0 * * h: torque control
(1)Replace "**" with the function number. Refer to the Output
function number table.
(2)Set the synthesis method of Axis A output and Axis B output
in 4bit (bit31 to 28) of "n".
n=0 (Axis A)
Axis A output state is output.
n=2 (Axis B)
Axis B output state is output.
n=6 (A or B)
The result of logical OR of Axis A and Axis B is
output.
n=7 (A and B)
The result of logical AND of Axis A and Axis B is
output.
Do not specify any other settings.
Example 1)
When SO1 pin is specified as Axis A INP,
set Pr4.10 to 00040404h
Example 2)
When SO2 pin is specified as Axis B INP,
set Pr4.11 to 20040404h
Example 3)
When SO1 pin is specified as Axis A ALM or Axis B ALM,
set Pr4.10 to 60010101h
Example 4)
When SO2 pin is specified as Axis A ALM and Axis B ALM,
set Pr4.11 to 70010101h
4
11
C
S
SO2 output
selection
-
-2147483648
to
2147483647
Assign functions to SO2 outputs.
Setup procedure is the same as described for Pr 4.10.